Communication via SIKONETZ 5
AP10S
Date: 04.09.2017 Art. No. 87826 Mod. status 269/17 Page 36 of 48
6.9.28 34h: Formation of the differential value
Calculation of the differential value is set via parameter 34h.
Parameter address
34h
Description
formation of the differential value
Access
rw
EEPROM
yes
Programming mode
yes
Data type
UNSIGNED 8
Default
0
Data content
0: DIFF = ACT – SET
1: DIFF = SET - ACT
6.9.29 35h: Key function enable2: Incremental measurement enable
The parameter 35h indicates whether setting of the position value as incremental
measurement is enabled via key actuation.
Parameter address
35h
Description
Key enable
Access
rw
EEPROM
yes
Programming mode
yes
Data type
UNSIGNED 8
Default
1
Data content
0: Incremental measurement disabled
1: Incremental measurement enabled
6.9.30 38h: Sensor type
The sensor type can be set via parameter 38h.
Parameter address
38h
Description
sensor type
Access
rw
EEPROM
yes
Programming mode
yes
Data type
UNSIGNED 8
Default
0
Data content
0: MS500H
1: GS04