7.2 Error number encoding
The following error messages are returned in case of wrong input.
Error number
Description
?1
input of illegal parameter number
?2
illegal value range
Table 18: Error number encoding
7.3 Service protocol commands list
Command
Length
Reply
Description
Ay
2/17
"AP10 SN5 zW xxxx>"
Device type / software version
y=0: hardware version; z = H
y=1: software version; z = S
L
1/2
">"
Calibration (see chapter 4.6.2: Calibration)
Sxxxxx
6/2
">"
System commands
x=00100: start alignment (see chapter 4.6.1:
Alignment travel)
x=11100: all parameters into basic state
After restart, the factory settings will be
active, this applies to bus protocol and baud
rate as well.
x=11101: reset all to factory settings, except
bus parameters
x=11102: only bus parameters into basic state
x=11105: activate bootloader
Z
1/11
"±xxxxxxxx>"
Output actual position
Table 19: Service protocol commands list