Functional Description
AP10S
Date: 04.09.2017 Art. No. 87826 Mod. status 269/17 Page 9 of 48
An additional target window (target window2) and an associated visualization can also be
configured (see parameter 31h: Target window2 (extended)).
With factory settings, the LED display has the following meaning:
There is no valid
set point2.
There is a valid set
point2.
Target window not reached!
The sensor must be moved in positive counting
direction in order to reach the target.
Target window not reached!
The sensor must be moved in negative counting
direction in order to reach the target.
Target window not reached!
The sensor must be moved in negative counting
direction in order to reach the target.
Target window not reached!
The sensor must be moved in positive counting
direction in order to reach the target.
Table 3: LED display
Control word (see chapter 6.3.4: Control word):
The set point is not displayed and positioning not monitored unless the set point2 is marked
as valid in the control word.
Status word (see chapter 6.3.5: Status word):
Upon reaching target window1, the static and dynamic target-window-reached bits are set in
the status word. The dynamic bit is deleted when leaving target window1. The user must
acknowledge the static bit.
Example Position monitoring:
Parameterization: Factory setting
Additionally: Set point2 = 100
Fig. 2: Positioning monitoring