Functional Description
AP10S
Date: 04.09.2017 Art. No. 87826 Mod. status 269/17 Page 9 of 48
An additional target window (target window2) and an associated visualization can also be
configured (see parameter 31h: Target window2 (extended)).
With factory settings, the LED display has the following meaning:
Operating state
LED
Status
Meaning
There is no valid
set point2.
both
off
Positioning disabled.
There is a valid set
point2.
LED left
off
Target window not reached!
The sensor must be moved in positive counting
direction in order to reach the target.
red
Target window not reached!
The sensor must be moved in negative counting
direction in order to reach the target.
green
Target window reached
LED right
off
Target window not reached!
The sensor must be moved in negative counting
direction in order to reach the target.
red
Target window not reached!
The sensor must be moved in positive counting
direction in order to reach the target.
green
Target window reached
Table 3: LED display
Control word (see chapter 6.3.4: Control word):
The set point is not displayed and positioning not monitored unless the set point2 is marked
as valid in the control word.
Status word (see chapter 6.3.5: Status word):
Upon reaching target window1, the static and dynamic target-window-reached bits are set in
the status word. The dynamic bit is deleted when leaving target window1. The user must
acknowledge the static bit.
Example Position monitoring:
Parameterization: Factory setting
Additionally: Set point2 = 100
Fig. 2: Positioning monitoring
100
+
-
Target
window1
95
105
LED left
Positioning monitoring
LED right