FMON10JEN 07.04.2017 Rev. 10J
38 (38)
12 Maintenance
WARNING
Before disassembling or removing the monitor, the monitor must be disconnect-
ed from its power source and all lubrication point oil connections to the monitor
must be closed.
WARNING
Before and after disassembling or removing the monitor make sure that the
monitor is not hot and/or environment is clean.
NOTICE
Do not use any solvent to wash flowmeters. Solvents may weaken or damage certain parts of
flowmeters.
NOTICE
All electrical components must be protected against oil splashes.
Spare parts, refer to section 16
You could find maintenance videos from http://www.skfmuurame.fi/videos/
12.1.1 Removing and reinstalling sensor
Before flowmeter cover is removed, the sensor must first be removed. Twist gently with a screwdriver at the
right-side upper edge of the sensor.
Arrow head in the sensor indicates the point where pressure can be applied. Applying pres-
sure elsewhere may damage the sensor.