4. Set the desired parameters.
5. Select [Save].
The settings are saved in the ClusterController and are then transmitted to all devices of the
affected device class. The save process is displayed on the user interface of the
ClusterController via an hourglass symbol and may take several hours if the DC input voltage
in the inverter is too low (e.g. at night).
7.2.2 Setting the Parameters of an Individual Device
The parameters that you are able to set for a device depend on the rights of your user group (see
Section4.1, page22).
Procedure:
1. Select the desired device in the system tree and select the menu Settings in the device menu.
2. Select the parameter group that contains the parameter which is to be configured. Note that it
may take a moment to read off the values since they are retrieved directly from the device.
3. Select [Edit].
4. Set the desired parameter.
5. Select [Save].
The settings are saved in the ClusterController and are then transmitted to the affected device.
The save process is displayed on the user interface of the ClusterController via an hourglass
symbol and may take several hours if the DC input voltage in the inverter is too low (e.g. at
night).
7.3 Deactivating the Webconnect Function of the Inverters
If the Webconnect function is activated for the inverters in the system, you should deactivate the
Webconnect function of the inverters to avoid unnecessary attempts by the inverters to connect with
SunnyPortal. The Webconnect function of the inverters is activated by default.
You have the following options:
Disabling the Webconnect function for multiple inverters simultaneously
Disabling the Webconnect function for an individual inverter
Disabling the Webconnect Function for Multiple Inverters Simultaneously
1. Select the system in the system tree and select the menu Settings in the device menu.
The individual device classes are displayed in brackets after the name of the parameter
group, e.g. Device (Communication products). It may take a moment for all the data
to be read out from the devices.
2. Select the parameter group External communication > Webconnect.
3. Select [Edit].
7 Device Configuration
SMA Solar Technology AG
User Manual 41ClusterController-BA-en-15

Table of Contents

Other manuals for SMA CLUSTER CONTROLLER

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMA CLUSTER CONTROLLER and is the answer not in the manual?

SMA CLUSTER CONTROLLER Specifications

General IconGeneral
Data LoggingYes
DisplayLCD
Power Supply24 V DC
Remote MonitoringYes
Protection ClassIP20
Communication InterfacesEthernet
Product TypeController
ManufacturerSMA

Related product manuals