Procedure:
1. Reset the password settings of the ClusterController via the display:
Select the display view Settings. To do this, simultaneously press and hold the [OK] and
[ESC] buttons on the keypad for two seconds.
The display view Settings opens.
Select the Reset password line and press [OK].
The display view Confirm the resetting appears.
Select OK and confirm with [OK].
The user password and the installer password are reset.
2. Log into the ClusterController as Installer with the default system password 1111.
The inverters are each displayed with a padlock symbol in the system tree.
3. Adapt the installer password of the ClusterController to the PUK of the desired inverter. As a
result, the inverter can be accessed again:
Select the ClusterController in the system tree and select the menu Settings > User
rights > Access control in the device menu.
Select [Edit].
In the field Set installer password, enter the PUK of the desired inverter as the new
system password.
In the field Confirm password, enter the new system password again.
Select [Save].
The ClusterController changes the system password for the user group Installer
and the inverter is no longer displayed with a padlock symbol in the system tree.
4. To unlock additional inverters, repeat step 3 for the desired inverters.
5. Adapt the installer password and the user password of the ClusterController to the desired
system passwords:
Select the ClusterController in the system tree and select the menu Settings > User
rights > Access control in the device menu.
Select [Edit].
In the field Set installer password, enter the desired system password for the user
group Installer as a new system password.
In the field Confirm password, enter the new system password again.
In the field Set user password, enter the desired system password for the user group
User.
In the field Confirm password, enter the new system password again.
Select [Save].
The ClusterController changes the system passwords of both user groups and transmits the
changed system passwords to the inverters.
15 Passwords and SMA Grid Guard
SMA Solar Technology AG
User ManualClusterController-BA-en-1582

Table of Contents

Other manuals for SMA CLUSTER CONTROLLER

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMA CLUSTER CONTROLLER and is the answer not in the manual?

SMA CLUSTER CONTROLLER Specifications

General IconGeneral
Data LoggingYes
DisplayLCD
Power Supply24 V DC
Remote MonitoringYes
Protection ClassIP20
Communication InterfacesEthernet
Product TypeController
ManufacturerSMA

Related product manuals