Table 5.4-13 Alarms that allow continuous pump operation (2/2)
Alarm
No.
Alarm name
Alarms that allow
continuous pump
operation
Operation
AL28
High Electric conductivity
(Option D only)
[OFF] / [WRN]
-
AL29
No Power Supply
FLT
AL30
Digital input 1
[OFF] / [WRN]
-
[FLT]
AL31
Digital input 2
[OFF] / [WRN]
-
[FLT]
AL34
Communication
[OFF] / [WRN]
-
[FLT]
AL35
Ambient Temp.
[OFF] / [WRN]
-
AL36
Maintenance
[OFF] / [WRN]
-
AL37
Refrigeration Circuit
[FLT]
AL38
Sensor
[FLT]
×
AL39
Controller
[FLT]
×
AL40
Compressor Inverter
[FLT]
AL41
Compressor Inverter Comm.
[FLT]
AL42
Pump Inverter
[FLT]
×
AL43
Pump Inverter Comm.
[FLT]
×
Default setting.
“FLT” : Operation stops when alarm occurs; “WRN”: operation continues when alarm occurs;
“OFF”: alarm is disabled.