SOLO BETA User Manual
- “The Monitor Mode” enables you to keep monitoring the top 10 variables continuously
without the need to send a read command every time, so by enabling the Monitor mode
you will receive continuously the sampled values for:
1. VA: 3 phase Motors phase A voltage (BLDC, PMSM, ACIM)
2. VB: 3 phase Motors phase B voltage (BLDC, PMSM, ACIM)
3. IA: 3 phase Motors phase A Current (BLDC, PMSM, ACIM)
4. IB: 3 phase Motors phase B Current (BLDC, PMSM, ACIM)
5. VBUS : The power supply voltage ( BUS / Battery voltage )
6. IM: The DC motor Current
7. VM: The DC motor Voltage
8. Iq: The quadrature Current in 3 phase motors ( current acting in torque generation)
9. Id: The direct Current in 3 phase motors
10. Speed: The speed measured or estimated by SOLO both in Sensorless and in
Sensor-based methods
These values are sampled all at the same time each with 20kHz of sampling rate, and the
Monitoring will continue until you disable it. This is a very interesting feature for those of
applications in which keeping track of all the vital parameters is vital.
www.solomotorcontrollers.com
January 2021 - Revision V_1.0.5 Copyright © 2020, All right Reversed. SOLO motor controllers.