219
Overall Control Panel Settings
Chapter
  Chapter 17  Control Panel Setup
17
Control Panel Setup
Overall Control Panel 
Settings
In panel setup, you carry out settings particular to the 
control panel.
Interchanging the Bank Order or 
Disabling Operation
You can set the assignments for the M/E and PGM/PST 
banks, and then enable, disable, or inhibit operations for 
each of the M/E and PGM/PST banks.
1
In the Engineering Setup >Panel >Config menu 
(7321), select the Bank you want to set.
The Bank selection here indicates the physical position 
on the control panel.
Corresponds to the 2nd row and 3rd row from the top; 
the 1st row cannot be used.
2
Select the bank that you want to assign to the selected 
Bank number in the <M/E Assign> group.
The status area shows the interchanged state of the 
banks.
It is not possible to assign the same M/E logical bank 
to more than one physical bank. Be sure to make 
different M/E assignments.
3
For the selected Bank number, in the <M/E 
Operation> group, select one of the following.
Enable: Enables panel display and operation of the 
bank.
Disable: Enables only panel display, and disables 
operation of the bank.
Inhibit: Disables both the panel display and operation 
of the bank.
When this is set to Inhibit, snapshots of the bank are 
not recalled.
Linking Switcher Bus and Router 
Destination
To provide links between the switcher bus and router 
destination, make the following settings as required.
Matrix selection: Selects the target of link setting from 
the eight matrices (1 to 8).
Matrix position definition: Sets the start address and 
level for the source and destination on the S-Bus.
Link table setting: Links a switcher cross-point button 
and matrix source.
Link bus setting: Links a switcher bus address and router 
destination.
Selecting a matrix number
1
Open the Engineering Setup >Panel >Config 
>External Bus Link menu (7321.3).
2
Set the following parameters.
3
Press [Link Matrix Set].
To delete a link
With the link selected, press [Clear].
Defining the position of a matrix
Specify where in the 1024 × 1024 S-Bus space the link 
matrix is to be provided, by setting the source and 
destination start address.
For the matrix selected in the External Bus Link menu, use 
the following procedure.
Notes
Notes
No. Parameter Adjustment
1 Link No Link number
2 Link Matrix Matrix number