Wipe Snapshots
Chapter 5 Wipes
a) 1 p. 85.
To move the pattern from its current position to
the center through the course of a transition
Press [Auto Center], turning it on.
Rotating the wipe pattern (Rotation)
1
In the <Rotation> group of the Key1 Wipe Adjust
menu, select the rotation type.
Angle: Incline the pattern through a fixed angle.
Speed: Rotate at a speed rate.
Magnitude: Rotate the pattern through a fixed angle
during the course of the transition.
2
Depending on the selection in step 1, set the following
parameters.
When Angle is selected
a) 1 p. 86.
When Speed is selected
a) 1 p. 86.
When Magnitude is selected
a) 1 p. 86.
Setting the wipe pattern aspect ratio
(Aspect ratio)
1
In the Key1 Wipe Adjust menu, press [Aspect],
turning it on.
2
Set the following parameter.
a) 1 p. 86.
Replicating the wipe pattern
(Multiplication)
1
In the Key1 Wipe Adjust menu, press [Multi], turning
it on.
2
Set the following parameters.
a) 1 p. 87.
Wipe Snapshots
You can snapshot and save a wipe pattern together with the
current settings of its modifiers and pattern limit in a
dedicated register for recall when required. There are 10
wipe snapshot registers on each bank.
Wipe snapshots can be saved or recalled using the Flexi
Pad or a menu operation.
For details about Flexi Pad operations, 1 “Wipe Pattern
Operations in the Flexi Pad” (p. 90).
Wipe Snapshot Operations with the
Menus
Use the Wipe Adjust menu in each switcher bank.
When operating from the M/E-1 bank, for example, open
the M/E-1 >Wipe >Wipe Snapshot menu (1157).
No. Parameter Adjustment
1 Position H Horizontal position
a)
2 Position V Vertical position
a)
No. Parameter Adjustment
1 Angle Rotation angle of pattern
a)
No. Parameter Adjustment
1 Speed Rotation speed of pattern
a)
No. Parameter Adjustment
1 Angle Angle of pattern at start of
transition
a)
2 Magnitude Amount of rotation through
course of transition
a)
No. Parameter Adjustment
1 Aspect Aspect ratio
a)
No. Parameter Adjustment
1 H Multi Number of repetitions of pattern
horizontally
2 V Multi Number of repetitions of pattern
vertically
3 Invert Type Replication layout
a)
Memory recall buttons