EasyManua.ls Logo

Sony MVS-3000 System - Setting Trackball and Button Double-Click Sensitivity; Setting the Macro Execution Mode; Screen Saver and Other Settings; Using the Menu Display Screen Saver

Sony MVS-3000 System
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
238
Screen Saver and Other Settings
Chapter 17 Control Panel Setup
Setting Trackball and Button Double-
Click Sensitivity
You can adjust the sensitivity of the trackball and button
double-clicks.
1
Open the Engineering Setup >Panel >Operation
>Sensitivity menu (7326.5).
2
Make the following settings as required.
Trackball and Z-ring sensitivity in normal mode:
In the <Trackball Normal Mode> group, select
[×1], [×2], or [×4].
Trackball and Z-ring sensitivity in fine mode: In the
<Trackball Fine Mode> group, select [
1
/
2
], [
1
/
4
],
or [
1
/
8
].
Touch sensitivity for recalling menus by double-
clicking buttons: In the <Double Click> group,
select [Fast], [Normal], or [Slow].
Setting the Macro Execution Mode
1
Open the Engineering Setup >Panel >Operation
>Macro menu (7326.6).
2
In the <Macro Execution Mode> group, select the
macro execution mode.
Normal: Normal execution mode
Step: Step execution mode
3
When making a macro attachment setting, select
whether or not to enable cross-point button operations
in the <Attachment Setting Mode> group.
With Btn Function: Enables cross-point button
operations.
W/o Btn Function: Disables cross-point button
operations.
4
Using the <Macro 2nd Recall Mode> group, set the
action to occur during macro execution or when a
macro is stopped, if the cross-point button with the
macro attachment set is pressed again.
Continue: Resumes execution of a macro that has
been stopped (executing macros continue
execution).
Cancel: Terminates execution of a stopped or
executing macro.
5
Using the <Macro Recall Override> group buttons, set
the action to occur during macro execution or when a
macro is stopped, if another macro is recalled.
Disable: Ignores macro recalls.
Enable: Executes other macros.
To have a cross-point button with a macro
attachment set lit continuously
Press [Attchd Btn Indication], turning it on.
When the [MCRO ATTCH ENBL] button in the cross-
point control block is on, the cross-point button with a
macro attachment is constantly lit green.
Screen Saver and Other
Settings
Using the Menu Display Screen
Saver
1
In the Engineering Setup >Panel > Maintenance menu
(7327), press [Screen Saver], turning it on.
2
Adjust the following parameter.
Using Panel Sleep Mode
The brightness of all indicators on the control panel, with
the exception of the menu screen, can be dimmed.
1
In the Engineering Setup >Panel >Maintenance menu
(7327), press [Panel Sleep Mode], turning it on.
2
Set the following parameter.
Adjusting the Brightness
You can adjust the brightness of the following hardware
parts.
LCD Btn Brightness: Adjusts the brightness of the LCD
buttons in the Flexi Pad.
Display Brightness: Adjust the brightness of the organic
EL panel for the source name displays, etc.
Switch Brightness: Adjusts the brightness of the panel
switches.
No. Parameter Adjustment
1 Sleep Time Time until screen saver starts
operation
No. Parameter Adjustment
1 Sleep Time Time of inactivity until panel
sleep mode starts.