EasyManua.ls Logo

Sony MVS-3000 System - Making Link Table Settings; Linking Cross-Point Buttons and GPI Output Ports; Setting Links between M;E Banks

Sony MVS-3000 System
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
253
Settings Relating to Function Links
Chapter 18 Switcher Setup
Making Link Table Settings
1
Open the Engineering Setup >Switcher >Link
>Internal Bus Link >Link Table Select menu (7336.3).
2
Select the link source and link destination files.
3
To confirm the selection, press [Link Src Set].
This links the link destination signal to the signal
selected as Main No.
To initialize the set source address
Press [Init Link Table].
Check the message, then press [Yes].
Linking Cross-Point Buttons and
GPI Output Ports
To link cross-point buttons or the [CUT] and [AUTO
TRANS] buttons in the cross-point control block, and GPI
output ports, use the following procedure.
1
Open the Engineering Setup >Switcher >Link >GPI
Link menu (7336.4).
2
Select the GPI output port.
3
Press [GPI Link Adjust].
The GPI Link Adjust menu (7336.5) appears.
4
Select the setting to apply. For each GPI port there can
be up to eight links.
5
In the <Video/Button> group, press [Select].
The selected video or button name is reflected in the
status area.
To clear a video/button name link
Make the selection to which the setting applies, then
press [Clear] in the <Video/Button> group.
6
To select for each bus whether the GPI link setting is
enabled or disabled, select the bus to which the setting
applies.
7
In the <Bus> group, select any of the following.
Enable: Enables the GPI link setting for the selected
bus.
Disable: Disables the GPI link setting for the selected
bus.
All Enable: Enables the GPI link setting for all buses.
Setting the delay value
1
In the Engineering Setup >Switcher >Link >GPI Link
Adjust menu (7336.5), select the output port for which
you want to set the delay value, and the corresponding
delay value.
2
Press [Delay Set].
Setting the operation mode when selecting
M/E reentry inputs
When you select a re-entry signal in the cross-point control
block of an M/E block (upstream M/E block), the output of
the upstream M/E block is read in. You can set the system
so that when a GPI link is set for the cross-point selected
on the A bus
1)
of the upstream M/E block this triggers the
GPI output.
In the Engineering Setup >Switcher >Link >GPI Link
menu (7336.4), set [Re-Entry Enable] to On or Off.
When set to On, the GPI is executed upstream.
1) When the bus toggle is set to Off, the applicable bus depends on the
position of the fader lever.
For re-entry, “upstream” applies to a single stage only.
This setting is common to all GPI output ports.
GPI output execution on the upstream M/E block is only
possible on buses for which GPI Link is set to “Enable”
in the GPI Link Adjust menu.
GPI outputs are executed when reentry signals are
selected under the following conditions.
- When selected using buttons in cross-point control
block
- When selected by macro execution
- When selected on the AUX bus remote panel
Setting Links between M/E Banks
The operations for which you can link two M/E banks are
as follows.
Transition execution (auto transition, cut, and fader lever
operation)
Next transition selection
No. Parameter Adjustment
1 Link No Link to which setting applies
3Link Table
No
Link table selection
No. Parameter Adjustment
1 GPI Port GPI output port to be configured
5 Delay Delay value for the output port
Notes