EasyManua.ls Logo

Sony MVS-3000 System - Making a Link Setting for Key Transition; Interfacing with External Devices; Making 9-Pin Port Device Interface Settings; Making Switcher Processor GPI Input Settings

Sony MVS-3000 System
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
254
Interfacing with External Devices
Chapter 18 Switcher Setup
Transition type selection
1
Open the Engineering Setup >Switcher >Link >M/E
Link menu (7336.6) and specify the link number to set.
2
In the <M/E Select> group, select [Master M/E] (link
source).
3
Select the M/E or PGM/PST link source, then press
[M/E Set].
4
In the <M/E Select> group, select [Linked M/E] (link
destination).
5
Select the M/E or PGM/PST bank you want to be the
link destination, then press [M/E Set].
To link the banks not only for transition execution
but also for the other operations
Press [Transition Only], turning it off.
To release a link
Use the same operation as in step 1 to select the link
number for which you want to release the link setting, then
press [Clear].
Making a Link Setting for Key
Transition
The operations for which you can link two banks are the
following independent key transition operations.
Auto transition
Turning the key on or off
1
Open the Engineering Setup >Switcher >Link >Key
Transition Link menu (7336.7) and specify the link
number to set.
2
In the <Key Select> group, select [Master Key] (link
source).
3
Select the key you want to be the link source, then
press [Key Set].
4
In the <Key Select> group, select [Linked Key] (link
destination).
5
Select the key you want to be the link destination, then
press [Key Set].
To release a link
Use the same operation as in step 1 to select the link
number for which you want to release the link setting, then
press [Clear].
Interfacing with External
Devices
Making 9-Pin Port Device Interface
Settings
The description in this section takes the Remote S1 port as
an example. For other Remote ports, carry out the same
process as required.
1
Open the Engineering Setup >Switcher >Device
Interface >Remote Assign menu (7337.1).
2
Select the device interface you want to set for the
Remote port from the <Remote S1> group.
Editor A: Assigns Editor A to the Remote S1 port.
Editor B: Assigns Editor B to the Remote S1 port.
AUX: Assigns AUX to the Remote S1 port.
The device interfaces which can be selected for
Remote S2 are the same as for Remote S1.
Making Switcher Processor GPI
Input Settings
1
Open the Engineering Setup >Switcher >Device
Interface >GPI Input menu (7337.2).
2
Select the setting to apply.
3
In the <Trigger Type> group, select the trigger type.
(Rising Edge): Applies the trigger on a rising
edge of an input pulse.
(Falling Edge): Applies the trigger on a falling
edge of an input pulse.
(Any Edge): Applies the trigger on a change in
the polarity of the input signal.
(Level): Carries out the specified operation
when the input is low or high.
No Operation: Applies no trigger on an input pulse.
4
In the <Target> group, select the action block.
M/E-1 and P/P: Sets an action for the M/E or PGM/
PST bank.
Common/Setup: Sets an action for something other
than the above, or a setup action.
5
Select the action.
6
Press [Action Set] to confirm the action selection.