225
Cross-Point Settings
Chapter 17 Control Panel Setup
Button Assign menu (7322.1), select one of the following
for each cross-point table.
Hold: Acts as a shift button, and the shifted version of the
cross-point buttons is enabled while the button is held
down.
Lock: Acts as a shift button, and pressing the button
toggles between the shifted version and the unshifted
version.
Off: Acts as cross-point button 24.
Setting the action of the [SHIFT] button in
the cross-point control block
The function of the shift button is set in the <Display Shift
Mode> group of the Engineering Setup >Panel >Xpt
Assign >Main, V/K Pair Assign menu (7322.5) or
Engineering Setup >Panel >Xpt Assign >Table Button
Assign menu (7322.1).
Shift All Bus: When this is On, it functions as a shift
button for all buses. When this is Off, it functions as a
shift button for the source name display section.
It is not possible to make this setting separately for each
of the M/E and PGM/PST banks.
“Shift All Bus” is only valid when the cross-point button
shift operation (see previous item) is set to “Lock” or
“Off.”
Setting the source signal name
1
Open the Engineering Setup >Panel >Xpt Assign >Src
Name >Src Color menu (7322.6).
2
Select the signal to be set.
“Primary33” to “Primary48” and signal names relating
to DME and M/E-2 are disabled, even if selected.
3
Press [Source Name].
4
Enter a name of not more than 16 characters, then
press [Enter].
Sequential names for multiple signals
When you specify a number at the end of a signal name, all
of the signals in the range selected are automatically
assigned names ending with sequential numbers.
Example: To assign sequential names to source signal 2
through source signal 4
1. In step 2 above, set the [Source No] parameter to
“2,” and set the [Num] parameter to “3.”
2. Set the name of source signal 2 to “CAM2.”
The name “CAM3” is assigned automatically to
source signal 3, and the name “CAM4” is assigned
automatically to source signal 4.
Setting the Cross-point Button Color
for Each Signal
You can set the color of cross-point buttons for
background A bus and background B bus on the M/E and
P/P banks.
1
Open the Engineering Setup >Panel >Xpt Assign >Src
Name/Src Color Select menu (7322.6).
2
Select the target color.
“Primary33” to “Primary48” and signal names relating
to DME and M/E-2 are disabled, even if selected.
3
In the <Source Color> group, press one of [User Color
1] to [User Color 3].
To change the color assigned to User Color 1 to 3
1
Press the [User Color Select] button.
The User Color Select menu (7322.12) appears.
2
Select the object to set in the “Target” field on the left.
3
Select the desired color in the “Color” field on the
right.
The selected color is displayed in the list on the left.
4
Repeat steps 2 and 3 above to change colors, as
required.
5
Press [Execute].
Copying Cross-Point Assign Tables
The contents of a cross-point assign table can be copied to
another cross-point assign table, and vice versa.
The contents of a sub table cannot be copied to the main
table.
1
Open the Engineering Setup >Panel >Xpt Assign
>Table Copy menu (7322.8).
2
Select the copy source and copy destination table
numbers.
Notes
No. Parameter Adjustment
1 Source No Source signal selection
2 Num Number of source signals to be
selected