42
Power Supply and Connectors
Chapter 2 Names and Functions of Parts
ICP-3000 Control Panel
Top panel
POWER switch and status indicators A and B
When power is supplied to the AC IN A and B connectors
on the rear panel, the status indicators (green) light. If you
press the POWER switch under this condition, 1 lights
green and the panel turns on.
Shutting down the control panel
Press the [Shutdown] button in the top menu list or top
menu window, and follow the on-screen instructions. After
the menu screen goes fully black, check that the control
panel power switch indicator 1 has gone out.
You can forcibly turn off the power without shutting down
by pressing and holding the POWER for about five
seconds.
If status indicator A or B does not light even when power
is supplied to the AC IN A and B connectors, there may
be a fault in the power circuits. Disconnect the cords
from the AC IN A/B connectors, and contact your Sony
service representative.
If you force shutdown without performing shutdown
processing, setting data may not be saved.
Shut down the control panel before turning off the AC
power supply (or disconnecting the power cord).