4-25
Washer Operation Operator Manual 122997-341
4.11 DRAIN Function To access Manual DRAIN functions, proceed as follows:
1. From Manual Control Menu, press SELECT CYCLE touch pad
until DRAIN is flashing. Display shows:
FILL DRAIN
PUMP/DRV DRIVE
__indicates flashing position.
2. With DRAIN flashing, press CYCLE/START touch pad. Display
shows DRAIN Menu:
SUMP ALK.TANK
ACIDTANK COOLDOWN
__indicates flashing position.
NOTE: During Manual Drain, note the following:
1) If Acid Tank Hardware and/or Cool Down Tank options are set
OFF (set in Misc. Values function), Acid Tank and Cool Down
selections do not appear on display screen.
2) If necessary, manual functions can be aborted at any time by
pressing STOP/RESET touch pad.
4.11.1 Draining Sump To drain sump manually, proceed as follows:
1. From Drain Menu, press SELECT CYCLE touch pad until SUMP
is flashing. Display shows:
SUMP
ALK.TANK
ACID TANK COOLDOWN
__indicates flashing position.
2. With SUMP flashing, press CYCLE/START touch pad. If sump is
not already full, display shows:
FILLING SUMP...
PRESS STOP TO ABORT
3. When sump is full, display shows:
SUMP FULL
After a delay of three seconds, jet valve(s) closes, sump drain
valve(s) opens, and display shows:
DRAININGSUMP...
PRESS STOP TO ABORT
4. Pump runs for DRAIN TIME. If unit is provided with a cooldown
tank and cooldown tank is not empty, display shows:
STANDBY - COOLDOWN
TANK COOLING
... and:
STANDBY - COOLDOWN
TANK DRAINING