Lubricate the lift mast and chains
with chain spray
NOTE
If there is excessive dust on the chain affect-
ing the ability of the lubricant to permeate the
chain, the lifting chain must be cleaned.
Place an oil collecting trough under the lift
mast
Carry out cleaning with an alkyl derivative
such as an industrial diesel fuel cleaning
agent (please comply with the manufactur-
er's safety instructions).
Additives may not be used if using a steam
nozzle.
Immediately blow the chain dry after clean-
ing to remove water both on the chain sur-
face and inside the hinge pins. Move the
chain several times during the blow-drying
process.
Immediately apply chain spray and keep the
chain moving while doing so.
NOTE
The lifting chains are a safety component. The
use of cold cleaning agents, chemical cleaning
agents, corrosive liquids or liquids containing
acid or chlorine will cause direct damage to
the chains.