4 | Drive controller technical data STÖBER
14
11/2017 | ID 442793.00
4 Drive controller technical data
This chapter contains the general technical data and the electrical data for the SC6 drive
controller. Additional technical data on the drive controller and accessories can be found in the
manual; see the chapter Detailed information [
}70].
4.1 General technical data
The following specifications apply to all drive controller types.
Device features
Protection class of the device IP20
Protection class of the
installation space
At least IP54
Radio interference suppression Integrated line filter in accordance with EN 61800-3:2012,
interference emission class C3
Overvoltage category III in accordance with EN 61800-5-1:2008
Test symbols
Tab. 2: Device features
Transport and storage conditions
Storage/
transport temperature
−20°C to +70°C
Maximum change: 20K/h
Relative humidity Maximum relative humidity 85%, non-condensing
Vibration (transport) in
accordance with DIN
EN60068-2-6
5Hz ≤ f ≤ 9Hz: 3.5mm
9Hz ≤ f ≤ 200Hz: 10m/s²
200Hz ≤ f ≤ 500Hz: 15m/s²
Tab. 3: Transport and storage conditions
Operating conditions
Surrounding temperature
during operation
0°C to 45°C with nominal data
45°C to 55°C with derating −2.5%/K
Relative humidity Maximum relative humidity 85%, non-condensing
Installation altitude 0m to 1000m above sea level without restrictions
1000m to 2000m above sea level with −1.5%/100m
derating
Pollution degree Pollution degree 2 in accordance with EN 50178
Ventilation Installed fan
Vibration (operation) in
accordance with DIN EN
60068-2-6
5Hz ≤ f ≤ 9Hz: 0.35mm
9Hz ≤ f ≤ 200Hz: 1m/s²
Tab. 4: Operating conditions