EasyManuals Logo

Sun Microsystems StorageTek SL500 Reference Manual

Sun Microsystems StorageTek SL500
296 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #118 background imageLoading...
Page #118 background image
Initialize Element Status
90 SL500: Interface Reference Manual July 2008 Revision: F 96122
Initialize Element Status
The host uses the Initialize Element Status command (07h) to request an inventory
of the cartridge tapes held in the library. The library accepts this command for
compatibility, but does not perform any action.
At power-on the library performs an audit of and maintains the inventory during
operations. The library also performs an audit after someone has opened and
closed the front door.
An initiator can obtain inventory information for the library by using the Read
Element Status command.
TABLE 6-6 Initialize Element Status Command
Byte
Bit
76543210
0Operation Code (07h)
1 Ignored Reserved (00h)
2 Reserved (00h)
3 Reserved (00h)
4 Reserved (00h)
5 Control Byte (00h)

Table of Contents