Page #132 background image
Log Sense
104 SL500: Interface Reference Manual July 2008 Revision: F 96122
0009h Library Humidity
Limits
Set when general conditions inside the library exceed
the humidity specifications.
C
000Ah Library Temperature
Limits
Set when general conditions inside the library exceed
the temperature specifications.
C
000Bh Library Voltage Limits Set when the voltage supply exceeds specifications. C
000Ch Library Stray Tape Set when a cartridge was left in a drive because of a
previous hardware fault.
C
000Dh Library Pick Retry Set if the hand requires more than one try to pick a
cartridge from a cell or drive.
W
000Eh Library Place Retry Set if the hand requires more than one try to place a
cartridge into a cell.
W
000Fh Library Load Retry Set if the hand requires more than one try to place a
cartridge into a drive.
W
0010h Library Door Set if the door has been opened, and no library
motions are allowed. When the door is closed, the
library will IPL.
C
0011h Library Mail slot Set when the mail slot (cartridge access port) switch
has failed.
C
0012h Library Magazine Set when the library needs the magazine. C
0013h Library Security Set when the security was compromised. W
0014h Library Security Mode Set when the security mode was changed. I
0015h Library Offline Set when the library has been placed into maintenance
mode from the operator panel or a Web interface.
I
0016h Library Drive Offline Set when a drive was taken offline. I
0017h Library Scan Retry Set when more than one attempt is required to read a
bar code. The problem is caused when only part of the
bar code can be read. The library supports cartridges
with no labels.
W
0018h Library Inventory Set when the library detected an inconsistency in its
inventory.
C
0019h Library Illegal
Operation
Set when an unsupported SCSI command is sent to the
library. This is not a corrupted command detected for
flag 6.
W
001Bh Cooling Fan failure Set when the library cooling fan has failed W
001Ch Power Supply Set when a redundant power supply has failed inside
the library. Check the library users manual for
instructions on replacing the failed power supply.
W
001Dh Power Consumption Set when the library power consumption is outside the
specified range.
W
0020h Unreadable Bar Code
Labels
The library was unable to read the bar code on a
cartridge.
I
TABLE 6-18 TapeAlert Flags (Continued)

Table of Contents

Other manuals for Sun Microsystems StorageTek SL500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems StorageTek SL500 and is the answer not in the manual?

Sun Microsystems StorageTek SL500 Specifications

General IconGeneral
BrandSun Microsystems
ModelStorageTek SL500
CategoryStorage
LanguageEnglish

Related product manuals