Mode Sense (6)
136 SL500: Interface Reference Manual • July 2008 Revision: F • 96122
Mode Sense (6) Element Address Assignment Page Definitions:
PS The Parameters Saveable bit specifies that the library can save this page to
non-volatile memory and returns a value of 1.
Page Code Identifies the Element Address Assignment mode page and returns a
value of 1Dh.
Parameter Length Indicates the amount of element address data following this byte and returns a
value of 12h.
First Medium Transport
Element Address
Identifies the address of the robot and returns a value of 0h.
Number of Medium
Transport Elements
Identifies the number of hands within the library and returns a value of 0001h.
First Storage Element
Address
Identifies the starting address of the cartridge tape storage cells.
The default starting address is 03E8h
Number of Storage
Elements
Identifies the number of cartridge tape storage cells within the library.
The total number of cartridge tape storage cells depends on how the library is
configured.
First Import /
Export Element Address
Identifies the address of the first Import/Export element.
The default starting address is 000Ah.
Number of Import /
Export Elements
Identifies the total number of import/export cells.
First Data Transfer
Element Address
Identifies the address of the first tape transport installed in the library.
The default address is 1F4h.
Number of Data Transfer
Elements
Identifies the number of tape drives in the library, and the library returns the
configured count.