58
No. Function StepRange
Initial value
53 Change between B/T and switch with buttons A or B during sewing 0 0/1 1= Select with button B
54 Selection of button A function 2 0 : Only B/T operates
1 : Lift and drop needle plate with one movement.
2 : Lift needle plate with one movement.
Drop needle plate with two movements
3 : Slow performance when stopped
(1/2 stitch speed)
55 Selection of Button B function 0 0 : B/T delete insertion
1 : Lift and drop needle plate with one movement
2 : Slow performance when stopped
(1/2 stitch speed)
3 : Only B/T operates
56 Selection of speed during manual back tack during sewing 0 0/1 0 : current sewing speed
1: initial reverse speed
57 NOT USED
58 Thread Trimming Sequence Selection of SunStar Chain Stitch Machine 1 0/1 1
59 Thread Trimming Sequence Selection of other Company chain Stitch Machine 0 0/1 1
60 Selection of reverse rotation after trimming 0 0/1 1:selection of reverse direction
61 Reverse rotation distance when selecting reverse rotation after thread trimming 20degree 0~250 1degree
62 When machine stops fix pulley (When machine stops fix the motor by force) 0 0/1 1: fix when machine stops
63 Power to fix the A number 62 Pulley 40 10~100 1
64 Distance recovered after fixing A number 62 Pulley and rotating it by force 20degree 10~100 1degree
65 Select the motor rotating direction ( )
1 0/1 1 : clockwise
0 : counterclockwise
66 Target speed : If this speed is reached or passed, a signal saying 1000spm 40~9960 40spm
“Target speed has been reached”will appear.
(As an interior Port it is alloted and used in the ‘C’GROUP-Default is auxiliary)
67 Delay start setup 0 0/1 0=normal start
1=Delay start
68 Delay start time duration setup 3 3~250 1×100[ms]
69 Setup of needle bar's stop at the lowest position after trimming when the 0 0/1 0=disabled
pedal is pressed 1=enabled
70 Setup of the duration of needle bar's stop at the lowest position after 100 100~250 1[ms]
trimming when the pedal pressed
71~75 Not Used -- -
76 Setting pattern sewing extension 0 0/1 0 : No pattern extension
1 : Pattern extension
77 Automatic changes of twin needles 0 0/1 0 : Teach stitch not used
1 : Teach stitch used
78 Start Backtack ON Duration 4[ms] 4~1020[ms]
79 Start Backtack OFF Duration 4[ms] 4~1020[ms]
80 End Backtack ON Duration 4[ms] 4~1024[ms]
81 End Backtack OFF Duration 100[ms] 4~1020[ms]
82 Stitch width reduction during backtacking 0 0/1 0=disabled
1=enabled
83 Not Used
84~87 Not Used -- -
88 Automatic PF lift and left/right needle solenoid lift 1
0 : Enable(in the event of using an electronic solenoid)
Enable/disable the solenoid OFF function after maintain
1 : Disable(in the event of using a pneumatic solenoid)
89 Upon trimming for a chain-type model, enable/disable the needle auto lift. 0 0/1
0=disabled
1=enabled
clockwise /counterclockwise
CCW
CW
Caution
If the specific items of the parameter are changed carelessly, they could break down or damage the machine, so the
user must be well-trained before using it.
4[ms]
(Parameter run when the Backtack
accuracy function is used)