EasyManua.ls Logo

Suzuki LT-A750X/P - Page 284

Suzuki LT-A750X/P
711 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1I-11 Starting System:
Installation
Install the starter clutch in the reverse order of removal.
Pay attention to the following points:
When inserting the one way clutch (1) into the guide
(2), fit the flange “A” in the step of the guide (2).
NOTE
Be sure to seat the flange “A” of the one way
clutch (1) to the guide (2).
Install the guide to the generator rotor.
NOTE
The arrow mark “B” must face the generator
rotor side.
Apply thread lock to the bolts, and then tighten them
to the specified torque.
: Thread lock cement 99000–32030
(THREAD LOCK CEMENT SUPER 1303 or
equivalent)
Tightening torque
Starter clutch bolt (a): 26 N·m (2.6 kgf-m, 19.0 lb-
ft)
Apply engine oil to the bearing of the starter driven
gear.
Install the generator rotor assembly onto crankshaft.
Refer to “Generator Removal and Installation in
Section 1J (Page 1J-4)”.
Apply molybdenum oil solution to the inside of
bushings.
1
2
“A”
I831G1190033-01
I718H1190031-01
“B”
I831G1190034-01
(a)
(a)
I831G1190035-01
I831G1190036-01
I831G1190037-02