3-40 ENGINE
Hold the generator rotor with the rotor holder and remove the
starter clutch bolts.
% 09930-44530: Rotor holder
REASSEMBLY
Apply a small quantity of THREAD LOCK SUPER to the
starter clutch bolts and tighten them to the specified torque
while holding the rotor holder.
) 99000-32030: THREAD LOCK SUPER 1303
% 09930-44530: Rotor holder
# Starter clutch bolt: 10 N·m (1.0 kgf-m)
GENERATOR STATOR AND PICK-UP COIL
When replacing the generator stator
1 or pick-up coil
2,
apply THREAD LOCK to the generator stator set bolts and
pick-up coil set bolts and tighten them.
* 99000-32050: THREAD LOCK 1342