5
1
SYSTEMA EOLO RT rev. 09ENIT04052021
GENERAL RULES
1 GENERAL RULES
■ These appliances are designed and built according to EU Regulation 2016/426 (GAR).
■ Before using this appliance, please read this manual.
■ It is compulsory to comply with the contents of this manual, particularly as regards safety standards.
■ Systema declines all responsibility for direct or indirect damage to persons, animals or things deriving from failure to
observe the instructions contained in this booklet.
■ This instruction booklet is an integral and essential part of the appliance and must be carefully kept near the system for
any further consultation.
■ Carefully read the instructions and warnings contained in this booklet before installation and use as they provide impor-
tant information regarding safety, installation, use and maintenance.
■ If this manual is lost, contact the manufacturer immediately.
■ In the event of a change of owner or a new tenant, hand over all documentation regarding the heating system to the
new owner / tenant.
■ Upon delivery of the product, ensure the integrity and completeness of the product and its components. If the product
and / or its components do not match, contact the agency that sold the appliance.
■ At the end of the work, the installer must provide the owner with the necessary documentation to certify, that the instal-
lation
■ has been made in a workmanlike manner and complies with the regulations in force in the country and in the place of
installation of the product.
■ Temperatures that are too high in the heated environment are harmful to health as well as being a useless waste of
energy. Proper use of the appliance is recommended.
■ The manufacturer is responsible for the conformity of its product with the regulations in force at the time the product is
marketed.
■ The observance of the laws in force and the regulations for the design of systems, installation, use and maintenance
are the sole responsibility, for the relative competences of the designer, installer and user.
■ It is forbidden to distribute this product without notifying the manufacturer in advance about the country of nal installa-
tion of the appliance, in fact specic documentation is required based on the country of destination of the product itself.
■ Several appliances installed in the same room, or in directly communicating rooms, are considered as a single system,
with a heat input equal to the sum of the heat rates of the individual appliances.
■
■ WARNING
■ To guarantee the correct functioning of the appliances, it is essential to strictly follow the instructions given by the manu-
facturer, use original accessories and spare parts, and have the system serviced by professionally qualied personnel
(at least once a year).
■ Do not install the appliances in premises intended for artisanal or industrial activities in which the processing and ma-
terials in storage involve the risk of the formation of gases, vapors or dust which can give rise to res or explosions.
■ The rooms where the appliances are installed must have a permanent ventilation surface as per regulations current.
■ Entrust the installation, construction of the gas piping, electrical connection, initial start-up and maintenance to pro-
fessionally qualied personnel responsible in compliance with the national and local regulations in force in the country
where the system is installed and what is reported in the this booklet.
■ Create the gas supply system and electrical connections in compliance with the national and local regulations in force in
the country where the system is installed; moreover, where required, they must be designed by a qualied professional.
■ The systems (gas pipes, power supply, etc.) must be carried out without creating obstacles or risks for people.
■ Do not use gas pipes to earth electrical appliances.
■ Before starting the appliances check:
■ - that the data of the electricity supply and gas supply networks are compatible with what is reported in this manual
and on the plates of the appliances;
■ - the tightness of the gas supply system as required by the applicable standards, the exact sizing and that it is equip-
ped with all the safety and control devices prescribed by the standards in force;
■ - the correct construction and operation of the ue gas exhaust and combustion air intake duct;
■ - the correct construction and operation of the condensate discharge duct.
■ This appliance must only be used for the use for which it was expressly designed. Any other use is to be considered
improper and therefore dangerous.
■ The manufacturer declines all civil and criminal liability in the event of any damage to persons, animals or things
deriving from incorrect installation, adjustment and maintenance, from modications and tampering, from the use of
non-original spare parts and accessories, from improper and / or incorrect use of the appliance, from non-observance
of the instructions provided by the manufacturer itself and from the intervention of personnel not professionally qualied.
■ If the appliance is not used for long periods of time, it is recommended to carry out the following operations:
■ - set the main switch of the appliance and the main switch of the system to “o”;