7
1
SYSTEMA EOLO RT rev. 09ENIT04052021
GENERAL RULES
1.1 TERMINOLOGY USED IN THE MANUAL
Tab. 1.1 Dentions
TERMS DESCRIPTION
Damage
Physical damage, personal injury or deterioration of property, and/or contamination of the environment.
Danger
A potential source of damage.
Qualied professional
A person who is properly trained, prepared and/or has relevant technical experience in the subject, allowing him to
perceive risks and avoid dangers arising during the use of the product, and who has the necessary technical and pro-
fessional certicates, if this is stipulated by the current legislation.
Risk
Combination of the probability of the damage occurrence and its severity.
User
Person or entity using the devices.
Modulatig
The device can automatically adjust its heat output in a certain range, depending on the actual temperature of the airow
supplied to the room, or the actual temperature of the room, based on the control values set from the ground control
panel.
GCV (Unit MJ/m³)
Higher caloric value, the total amount of heat released by a unit quantity of fuel, when it is burned completely with
oxygen, and when the products of combustion are returned to ambient temperature. This quantity includes the heat of
condensation of any water vapor contained in the fuel and of the water vapor formed by the combustion of any hydrogen
contained in the fuel.
NCV (Unit MJ/m³)
Lower caloric value, the total amount of heat released by a unit quantity of fuel with a certain amount of water vapor,
when it is burned completely with oxygen and when the products of combustion are not returned to ambient temperature.
Nominal Heat Input
(unit kW)
It is the product of the lower caloric value (NCV) of the fuel used and the ow rate of fuel burned.
Nominal heat output
(unit kW)
It corresponds to the reduced heat input of the heat output lost to the chimney.
Two stages
The appliance is able to automatically adjust its own heat output in two distinct levels, according to the actual and
desired temperature of the air ow introduced into the environment (parameter Y6 on the SCP674V030 motherboard,
see paragraph 4.1.3).
Minimum capacity (kW)
minimum capacity’ means the minimum heating capacity of the warm air heater (P
min
), expressed in kW;
Nominal values of powers and
efciency
These are the maximum power and efciency values of an appliance specied and guaranteed by the manufacturer for
continuous operation.
Warm air heater
Warm air heater means an air heating product that transfers the heat from a heat generator directly to air and
incorporates or distributes this heat through an air-based heating system;
B1 warm air heater
B1 warm air heater’ means a warm air heater using gaseous/liquid fuels specically designed to be connected to a
natural draught ue that evacuates the residues of combustion to the outside of the room containing the B1 warm
air heater and for drawing the combustion air directly from the room; a type B1 warm air heater is marketed as
a B1 warm air heater only.
C2 warm air heater
C2 warm air heater means a warm air heater using gaseous/liquid fuels specically designed for drawing the
combustion air from a common duct system to which more than one appliance is connected and extracting ue gas to
the duct system; a type C2 warm air heater is marketed as a C2 warm air heater only
C4 warm air heater
C4 warm air heater means a warm air heater using gaseous/liquid fuels specically designed for drawing the
combustion air from a common duct system to which more than one appliance is connected and extracting ue gas to
another pipe of the ue system; a type C4 warm air heater is marketed as a C4 warm air heater only;
Master
Command and control panel / terminal for the management of the devices through a serial system. The devices must be
equipped with a SLAVE card for connection to the serial network.
Slave
Card (SCP674V202MB) installed on the machine equipped with a port for connecting the device to a serial network.

Table of Contents