3-130
25
Trial run
Trialrunsshouldbeperformedtoruninanassembledpumpandtoensurethatitdeliversthespecied
performance. Trial runs are preferably carried on a special test stand, but may be carried out with the
pump on the machine using the following manner:
(If the pump were disassembled because of a seized pump or an abnormally worn internal component,
besuretochangethehydraulicoilandreplacethelterswithnewonesbeforetryingtomakeatrial
run.)
(a) Install the pump on the truck. Install a pressure gauge on the oil pressure check port of the control valve.
(b) Loosen the relief valve adjustment screw and operate the pump at 500 to 1000 rpm for about 10
minutes.
Make sure the pressure is less than 1 MPa {10 kgf/cm
2
} [142 psi].
(c) Increase the pump speed to 1500 to 2000 rpm and let the pump operate for about 10 minutes.
(d) Keeping the pump speed at 1500 to 2000 rpm, increase the pressure by 2 to 3 MPa {20 to 30 kgf/cm
2
}
[284 to 427 psi] up to 17.7 MPa {180 kgf/cm
2
} [2560 psi], letting the pump operate at each pressure for
about5minutes.Operateeachcircuitfor5minutesandreplacethereturnlterwithanewone.
While increasing the pressure, check the oil temperature and pump surface temperature. Check also for
operating noise. If the oil temperature or pump surface temperature rises excessively, reduce the load
and drop the temperature before continuing the test.
(e) After the test is over, set the oil pressure for 17.7 MPa {180 kgf/cm
2
} [2560 psi], perform a discharge
test.
The pump discharge is checked by observing the lift speed.