EasyManua.ls Logo

Technogym Step 600 XTPRO - The Telemetric Heart Rate Signal Is Incorrect

Technogym Step 600 XTPRO
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
STEP 600 XTPRO: Service & Maintenance Manual - rev. 1.1
Page 6.13
6.6. THE TELEMETRIC HEART RATE SIGNAL IS INCORRECT
The machine generates this error if the receiver is disturbed by electromagnetic noise in the
surrounding environment.
THE HEART RATE
SIGNAL IS
INCORRECT
Is the minimum distance
between machines OK?
Is the receiver positioned
correctly, and are the
connecting cables correctly
routed?
Are there sources of
electromagnetic noise near
the receiver?
Move the machines to
the minimum distance
Position the receiver and
the cable correctly
Move the machine away
from the electromagnetic
source or attenuate the
power of the noise
NO
YES
NO
YES
NO
YES
1
A
Is the transmitter in good
working order?
Use a known good
transmitter
NO
2
YES
Continued on the following page.