EasyManua.ls Logo

Tektronix TG8000

Tektronix TG8000
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HD3G7 3 Gb/s SDI Video Generator module remote commands
Sets the video c
hannel for the ancillary payload to either Luma or Chroma.
Luma is the default value.
:OUTPut1:ANC
:VCH?
Returns the video channel for the ancillary payload.
:OUTPut1:ANC:LOCation <LINKA| LINKB>
Sets the location for the ancillary payload.
:OUTPut1:ANC:LOCation?
Returns the location for the ancillary payload.
:OUTPut1
:ANC:FIELd <0|1|2>
This command is applicable for interlaced and segmented frame formats. This
command
sets the ancillary payload e ither on Field 1 or Field 2 or both on
Field 1 & 2. The meaning of the arguments is : 0 = Field 1, 1= Field 2, and
2= Both Field1 & 2.
The Line numbers where Field1 and Field2 payload data is inserted can be set
using the two arguments (ln1, ln2) in the OUTP1:ANC:LINe command.
:OUTPut1:ANC:FIELd
Retur
ns the eld o n which the ancillary payload is set.
:OUTPut1:ANC:DATa?
Returns the ancillary data settings as a single block of data. Data is returned as
a sequence of integers, with parameters separated by commas. Data is returned
in t
he following order (line breaks are inserted here for ease of reading):
<Line1>,
<L
ine2>,
<Sample>,
<Video Channel>,
<Link Loc>,
<Parity>,
<Output Mode>,
<DID>,
<SDID>,
<CS>,
<Auto CS Selection>,
<Field Selection>
:OUTPut1:BLACk <0|1>
Sets the secondary output. If not set, the secondary output uses the same test
pattern as the primary output.
:OUTPut1:BLACk?