SDI7 Dual Channel SD/HD/3G SDI Video Generator module remote commands
Sets the line nu
mber(s) of the user-dened a ncillary data packet for the
selected generator output. Two values are required; the rst value is for the
Field 1 line number and the second value is for the Field 2 line number. For
non-interlaced formats, use the same line number for both values.
:OUTPut<1|2>:ANC:LINe?
Returns the line n umbers on which the user-dened ancillary data packet is
located.
:OUTPut<1|2>:ANC:SAMPle <NR1 >
Sets the starting sample number of the user-dened ancillary data packet for
the selected generator output. For example, a value of 1928 represents the
rst sample of HANC data space for 1920 1080 formats.
:OUTPut<1|2>:ANC:SAMPle?
Returns the starting sample number where the user-dened ancillary data
packet is located.
:OUTPut<1|2>:ANC:DID <Hexade cimal>
Sets the D ata Identier of the user-dened ancillary data packet for the
selected generator output. Valid 8-bit values are in the range #H00 to
#HFF, and valid 10-bit values are in the range from #H000 to #H3FF. The
ANC:PARITY setting determines whether 8-bit values or 10-bit values are
used.
:OUTPut<1|2>:ANC:DID?
Returns the Data Identier value of the user-dened ancillary data packet.
:OUTPut<1|2>:ANC:SDID <Hexad ecimal>
Sets the Secondary D ata Identier of the user-dened ancillary data packet
for the selected generator output. Valid 8-bit values are in the range #H00 to
#HFF, and valid 10-bit values are in the range from #H000 to #H3FF. The
ANC:PARITY setting determines whether 8-bit values or 10-bit values are
used. The SDID value is o nly used for Type 2 ancillary data, when the DID
is in the range from #H00 to #H7F.
:OUTPut<1|2>:ANC:SDID?
Returns the Secondary Data Identier value of the user-dened ancillary
data packet.
:OUTPut<1|2>:ANC:DBN <Hexade ciaml>
Sets the Data Bl
ock Number of the user-dened ancillary data packet for
the selected generator output. Valid 8-bit values are in the range #H00 to
#HFF, and valid 10-bit values are in the range from #H000 to #H3FF. The
ANC:PARITY setting determines whether 8-bit values or 10-bit values are
used. The DBN v alue is only used for Type 1 ancillary data, when the DID
is in the range from # H80 to #HFF.
Draft
154 TG8000 Multiformat Test Signal Generator Programmer Manual

Table of Contents

Other manuals for Tektronix TG8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TG8000 and is the answer not in the manual?

Tektronix TG8000 Specifications

General IconGeneral
BrandTektronix
ModelTG8000
CategoryPortable Generator
LanguageEnglish

Related product manuals