SDI7 Dual Channel SD/HD/3G SDI Video Generator module remote commands
:OUTPut<1|2>:
ANC:DBN?
Returns the Data Block Number value of the user-dened ancillary data
packet.
:OUTPut<1|2>:ANC:DC <NR1>?
Returns the Data Count
value of the user-dened ancillary data packet for
the selected generator output. The DC value determines how many User
Data Words (UDW) will be present in the packet. Valid DC values are in the
range from 0 to 255.
:OUTPut<1|2>:ANC:DC?
Returns the Data Count value of the user-dened ancillary data packet.
:OUTPut<1|2>:ANC:UDW:INDex <N R1>
Sets the index within the array of User Data Word (UDW) values for
subsequent :ANC:UDW:SET? queries.
:OUTPut<1|2>:ANC:UDW:INDex ?
Returns the current index within the array of User Data Wo rd (UDW) values.
This value is updated by both :ANC:UDW:INDex and :ANC:UDW:SET
operations.
:OUTPut<1|2>:ANC:UDW:SET <NR1 >,<Hexadecimal>
Sets the value of one User Data Word in the array used for the user-dened
ancillary data packet. The SET command takes two arguments: the index and
the data value. The index species the location within the array, from 0 to 255.
For the data value, valid 8-bit values are in the range #H00 to #HFF, and valid
10-bit values are in the range from #H00
0to#H3FF.TheANC:PARITY
setting determines whether 8-bit values or 10-bit values are used.
:OUTPut<1|2>:ANC:UDW:SET?
Returns the index and data value for one User Data Word in the array used for
the user-dened ancillary data packet. T he index location is set by a previous
:ANC:UDW:SET or :ANC:UDW:INDex command.
:OUTPut<1|2>:ANC:UDW:CLEAr
Clears all User Data Word values in the array used for the user-dened
ancillary data packet. All data values are set to zero (#H00 in 8-bit notation
or #H200 in 10-bit notation).
:OUTPut<1|2>:ANC:CS:MANual <H exadecimal>
Sets the Checksum value of the u ser-dened ancillary data packet. Valid
10-bit values are in the range from # H000 to #H3FF. This command is only
needed if the :ANC:CS:AUTO:STATE? value is false.
:OUTPut<1|2>:ANC:CS:MANual ?
Draft
TG8000 Multiformat Test Signal Generator Programmer Manual 155

Table of Contents

Other manuals for Tektronix TG8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TG8000 and is the answer not in the manual?

Tektronix TG8000 Specifications

General IconGeneral
BrandTektronix
ModelTG8000
CategoryPortable Generator
LanguageEnglish

Related product manuals