SDI7 Dual Channel SD/HD/3G SDI Video Generator module remote commands
Sets the value o
ftheK
X
parameter (horizontal frequency) for the zone plate
test pattern.
:OUTPut<1|2>:ZONE:KX?
Returns the value of the K
X
parameter for the zone plate test pattern.
:OUTPut<1|2>:ZONE:KXSQ <NR2>
Sets the value of the K
X
2
parameter (horizontal sweep) for the zone plate
test pattern.
:OUTPut<1|2>:ZONE:KXSQ?
Returns the value of the K
X
2
parameter for the zone plate test pattern.
:OUTPut<1|2>:ZONE:KXT <NR2>
Sets the value of the K
XT
parameter (temporal channel horizontal frequ ency)
for the zone plate test pattern.
:OUTPut<1|2>:ZONE:KXT?
Returns the value of the K
XT
parameter for the zone plate test pattern.
:OUTPut<1|2>:ZONE:KXY <NR2>
Sets the value of the K
XY
parameter (vertical channel horizontal frequency)
for the zone plate test pattern.
:OUTPut<1|2>:ZONE:KXY?
Returns the value of the K
XY
parameter for the zone plate test pattern.
:OUTPut<1|2>:ZONE:KY <NR2>
Sets the value of the K
Y
parameter (vertical channel frequency) for the zone
plate test pattern.
:OUTPut<1|2>:ZONE:KY?
Returns the value of the K
Y
parameter for the zone plate test pattern.
:OUTPut<1|2>:ZONE:KYSQ <NR2>
Sets the value of the K
Y
2
parameter (vertical sweep) for the zone plate test
pattern.
:OUTPut<1|2>:ZONE:KYSQ?
Returns the value of the K
Y
2
parameter for the zone plate test pattern.
:OUTPut<1
|2>:ZONE:KYT <NR2>
Sets the value of the K
YT
parameter (vertical channel vertical frequency) for
the zone plate test pattern.
:OUTPut<1|2>:ZONE:KYT?
Draft
TG8000 Multiformat Test Signal Generator Programmer Manual 169