AWVG7 Analog Wideband Video Generator module remote c ommands
Returns the cur
rent circle overlay state.
:OUTPut1:CIRCle:DIAMeter <num eric_value>
Sets the diameter of the displayed circle. The unit is the percent of active
picture height. You can s et the diameter from 0% to 100% in 1% steps. You
can also use MIN, MAX, or DEF instead of a numeric value.
:OUTPut1:CIRCle:DIAMeter?
Returns the diameter of the displayed circle.
:OUTPut1:CIRCle:POSition:H ORizontal <numeric_value>
Sets the horizontal position of the circle as it appears on
the active signal.
The unit is the percent of active picture width. You can set the position from
-50% to +50% in 1% s teps. You can also use MIN, MAX, or DEF instead of
a numeric value.
:OUTPut1:CIRCle:POSition:H ORizontal?
Returns the current horizontal position of the circle as it appears on the active
signal.
:OUTPut1:CIRCle:POSition:V ERTical <numeric_value>
Sets the vertical position of the circle as it appears on the active signal. The
unit is the percent of active picture height. You can set the position from
-50% to +50% in 1% s teps. You can also use MIN, MAX, or DEF instead of
a numeric value.
:OUTPut1:CIRCle:POSition:V ERTical?
Returns the current vertical position of the circle as it appears on the active
signal.
:OUTPut1:LOGO:STATe ON|OFF
Turns the logo overlay on the video signal on or off. You can use 1 or
0insteado
fONorOFF.
:OUTPut1:LOGO:STATe?
Returns the current logo overlay state.
:OUTPut1:LOGO:POSition:HOR izontal <numeric_value>
Sets the horizontal position of the logo as it appears on the active signal.
The unit is the percent of active picture width. You can set the position from
-100% to 0% in 0.1% steps. You can also use MIN, MAX, or DEF instead of
a numeric value.
:OUTPut1:LOGO:POSition:HOR izontal?
Returns the current horizontal position of the logo.
:OUTPut1:LOGO:POSition:VER Tical <numeric_value>
Draft