EasyManua.ls Logo

THERMACUT EX-TRAFIRE 45HD - Selecting the Cutting Mode; Connecting the Work Lead with the Work Lead Clamp

THERMACUT EX-TRAFIRE 45HD
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN - 28
7 Operation of the power supply EX-TRAFIRE
®
45HD
7.1.2 Selecting the cutting mode
7.1.3 Connecting the work lead with the work lead clamp
1 Remove contamination from the workpiece.
2 Clamp the work lead with the work lead clamp to the workpiece in order
to allow maximum electrical connection.
3 Do not clamp the work lead clamp to the material to be cut off.
4 Clamp the work lead with the work lead clamp as close as possible to the
cutting area in order to minimize electromagnetic fields.
Grid cutting
Briefly press the multifunction button
to activate the cutting mode.
The current is 20 – 45 A.
The pressure of the cutting gas is
4.2 – 5.6 bar.
Cutting
Briefly press the multifunction button
to activate the cutting mode.
The current is 20 – 45 A.
The pressure of the cutting gas is
4.2 – 5.6 bar.
Gouging/Marking
Briefly press the multifunction button
to activate the cutting mode.
Gouging:
The current is 20 – 45 A.
The pressure of the cutting gas is
2.3 – 4.5 bar.
Marking:
The current is 10 – 16 A.
The pressure of the cutting gas is
2.4 bar.

Table of Contents

Related product manuals