EX-TRAFIRE
®
45HD 8 Disconnecting the unit
EN - 33
7.8 Stopping the cutting process
Release the torch rigger to end the cutting process.
After releasing the torch trigger, the gas continues to flow for up to
45 seconds, depending on the set output current, in order to cool the
cutting torch and the consumables.
To end the gas post-flow period prematurely, briefly press and release
the torch trigger.
Press the torch trigger again to ignite the pilot arc.
8 Disconnecting the unit
1 Set the <POWER> switch to <OFF>.
2 Disconnect the device from the input power supply.
3 Disconnect the device from the gas supply.
CAUTION
Risk of injury due to hot parts
Parts may still be hot after the gas post-flow period ends. There is a risk of
burns.
Wear your personal protective equipment.
Allow the cutting torch to cool down for 5 – 10 minutes before
touching the parts.