Controller Operation 7-19
Unit Pretrip Report
When the Unit Pre-trip is complete, the controller displays the results:
PASS: Unit passed the test.
CHEC: Alarm conditions (check or stored alarms) were detected during the test. A dash (-) is displayed in front of these alarms
on the controller display to indicated that they were detected during a Unit Self-Check test.
FAIL: Shutdown alarm conditions were detected during the test and the controller stopped the unit to prevent possible
damage. The Unit Self Check test was NOT completed.
Entering a Start of Trip in the Data Logger
(Units Equipped with DAS Option Only)
1. Turn the unit On/Off switch to ON
2. Press the PRETRIP key until “SOT” appears in upper display.
3. With SOT in upper display, press the ENTER key to enter a Start of Trip marker in the data logger.