Maintenance Inspection Schedule 4-9
UNIT MODELS: SLX, SLXe SPECTRUM
The service technician is responsible for assessing the condition of
all parts & components found during any service operation to be in
a condition suitable for further operation up to the next scheduled
service. If parts not considered in suitable condition, they should be
replaced.
Check/Inspect/Adjust/Change/Replace
INSPECTION
A SERVICE
Every 1000
hours
Or every 12
Months
(whichever
comes first)
SERVICE
B SERVICE
Every 3000
hours
Or every 24
Months
(whichever
comes first)
SERVICE
C SERVICE
Every 6000
hours
Or every 48
Months
(whichever
comes first)
EDAC Labour standard
1.5 hr 2.5 hrs 7.5 hrs
For SPECTRUM
8.0 hrs
REMOTE EVAPORATOR (S)
Electrical
Inspect wire harness for damaged wires or connections.
Check defrost operation, including drain heaters operation & defrost
termination.
Check fan motor start speed sequence and operation.
Refrigeration
Leak test remote evaporator & refrigerant lines - annually or as
required for F-Gas control regulations
Operate the two/three zones in inverted operation to confirm the unit's
ability to operate in reverse cycle for all zones.
Structural
Check defrost drains for leaks and water flow
Visually inspect unit for fluid leaks.
Visually inspect unit for damaged, loose, or broken parts.
Clean evaporator coils and defrost drains of loose debris.