EasyManuals Logo

Topcon DS Series User Manual

Topcon DS Series
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
17. RESECTION MEASUREMENT
101
7. If there are problems with the results of a point,
align the cursor with that point and press [OMIT].
“OMIT” is displayed to the right of the point.
Repeat for all results that include problems.
8. Press [RE CALC] to perform calculation again
without the point designated in step 7 The result
is displayed.
If there are no problems with the result, go to step
9.
If problems with the result occur again, perform
the resection measurement from step 4.
Press [RE_OBS] to measure the point
designated in step 7.
Press [ADD] in the second page when there is a
known point that has not been observed or when
a new known point is added.
If no points are designated in step 7, all the points
or only the final point can be observed again.
9. Press [OK] to finish resection measurement and
return to <Resection/Menu>. Only Z (elevation) of
the instrument station coordinate is set. N and E
values are not overwritten.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Topcon DS Series and is the answer not in the manual?

Topcon DS Series Specifications

General IconGeneral
BrandTopcon
ModelDS Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals