8
3. LASER SAFETY INFORMATION
The instrument is classified as the following class of Laser Product according to IEC Standard
Publication 60825-1 Ed.2.0: 2007 and United States Government Code of Federal Regulation FDA
CDRH 21CFR Part 1040.10 and 1040.11 (Complies with FDA performance standards for laser
products except for deviations pursuant to Laser Notice No.50, dated June 24, 2007.)
• EDM device is classified as Class 3R Laser Product when reflectorless measurement is selected.
When target (reflector) is set to prism or reflective sheet, the output is equivalent to the safer class 1.
Warning
• Use of controls or adjustments or performance of procedures other than those specified herein may
result in hazardous radiation exposure.
• Follow the safety instructions on the labels attached to the instrument as well as in this manual to
ensure safe use of this laser product.
• Never intentionally point the laser beam at another person. The laser beam is injurious to the eyes
and skin. If an eye injury is caused by exposure to the laser beam, seek immediate medical attention
from a licensed ophthalmologist.
Device Laser class
EDM device in objective lens
Light beam used for measurement
(When target (reflector) is set to N-prism.)
Class 3R
Light beam used for measurement
(When target (reflector) is set to prism or
reflective sheet.)
Class 1
Laser-pointer Class 3R
Laser plummet (option) Class 2
ࠩశߩญ
AVOID EXPOSURE-Laser radiation
is emitted from this aperture.
⋡߳ߩ⋥ធⵍ߫ߊࠍㆱߌࠆߎߣ
ࠢࠬ4ࠩຠ
,+5%
LASER RADIATION
AVOID DIRECT EYE EXPOSURE
/#:O9.&PO
MAX 5mW LD 625-695nm
CLASS3R LASER PRODUCT
IEC 60825-1 Ed. 2.0 : 2007
ࠩశ
* Laser beam emitted from here
(only when laser plummet
function is mounted)
Laser beam emitted
from here
*