MINTER Operation
P/N 7010-0736
4-9
See “MINTER” on page 1-11 for a full description of the MINTER.
To turn on/off the receiver, press the power button (Figure 4-5 on
page 4-9).
• When turning on, press the power button until the MINTER’s
LEDs briefly flash.
• When turning off, press the power button until the LEDs go out,
then release.
Figure 4-5. Power Button Functions
To start/stop logging data, press the FN button for 1–5 seconds
(Figure 4-6).
• During data recording, the REC LED is green. Use PC-CDU to
set the recording time interval. See “Recording Interval
parameter” on page 3-38 for details.
• The REC LED blinks green each time data is written to the SD/
MMC memory.
• If the REC LED is red, the receiver has run out of memory, has a
hardware problem, has no SD/MMC card, or contains an
improper OAF (see “Option Authorization File (OAF)” on
page 1-26 for more information).
Use PC-CDU to enable the desired FN key mode in the receiver,
either “LED blink mode switch” for static surveys or “Occupation
FUNCTION
FUNCTION
Power
Button
Press the power
button for about 1
second to turn the
receiver on/off.