DiagnosticsScreen(continued)
Throttleidentiesthethrottlecontrolsetting(involts)thatisusedbytheTEC
todeterminetheelectricmotorspeed.Rotatingthespeedwheelshould
changethesetting.Voltageforthrottlesettingsshouldrangefrom0.35to
4.80VDCdependingonthespeedwheellocation.
TargetRPMliststhedesiredelectricmotorRPMbasedonthespeedcontrol
setting.Rotatingthespeedwheelshouldchangethesetting.
MotorRPMidentiestheactualelectricmotorRPM.ThemotorRPMshould
beveryclosetotheT argetRPM.
12VSupplyindicatesthesuppliedvoltageavailableforthe12VDCcircuits
(InfoCenter,EZturnsensor).The12VSupplyshouldtypicallybeslightly
higherthan12.0VDC.
5VSupplyindicatesthesuppliedvoltageavailableforthe5VDCcircuit
(speedcontrol).The5VSupplyshouldtypicallybeslightlyhigherthan5.0
VDC.
CANbusidentieswhetherthemachinecommunicationbusstatusisnormal
ornot.
Toreturntothemainmenuscreenfromthediagnosticsscreen,pressthe
menu/backbutton(asindicatedbythe
atthebottomofthescreen).