DiagnosticsScreen(continued)
•Throttleidentiesthethrottlecontrolsetting(involts)thatisusedbytheTEC
todeterminetheelectricmotorspeed.Rotatingthespeedwheelshould
changethesetting.Voltageforthrottlesettingsshouldrangefrom0.35to
4.80VDCdependingonthespeedwheellocation.
•TargetRPMliststhedesiredelectricmotorRPMbasedonthespeedcontrol
setting.Rotatingthespeedwheelshouldchangethesetting.
•MotorRPMidentiestheactualelectricmotorRPM.ThemotorRPMshould
beveryclosetotheT argetRPM.
•12VSupplyindicatesthesuppliedvoltageavailableforthe12VDCcircuits
(InfoCenter,EZturnsensor).The12VSupplyshouldtypicallybeslightly
higherthan12.0VDC.
•5VSupplyindicatesthesuppliedvoltageavailableforthe5VDCcircuit
(speedcontrol).The5VSupplyshouldtypicallybeslightlyhigherthan5.0
VDC.
•CANbusidentieswhetherthemachinecommunicationbusstatusisnormal
ornot.
Toreturntothemainmenuscreenfromthediagnosticsscreen,pressthe
menu/backbutton(asindicatedbythe
atthebottomofthescreen).
ElectricalSystem:InfoCenterDisplay
Page5–30
Greensmaster
®
eFlex1800,2100and2120
12189SLRevE