Relay(ForModels04042,04043,04046and04049ttedwith04069)
g270848
Figure117
1.Relay
3.Bolt(2each)
2.Nut(2each)
4.Mountbracket
TherelayusedontheeFlexmachineis5terminal48Vrelayandlocatedbelow
theTECcontrollerinsidethebatterycover:refertoFigure117.
TestingtheRelay
1.Parkthemachineonalevelsurfaceandplacethetractionleverinthe
NEUTRALposition.TurnthekeyswitchtotheOFFpositionandremovethe
keyfromthekeyswitch.
2.Disconnectthebatterypack;refertoConnectingtheLithiumBatteryPack
(page5–7).
3.Removethe8boltsthatsecuresthebatterycovertothemountbracket;refer
toFigure90.Removethebatterycoverfromthemountbracket.
4.Notethepositionoftheconnectorsandwireharnessontherelayforthe
assemblypurposes.Disconnectthemachinewireharnessconnectorsfrom
therelay.Removetherelayfromthemachineforeaseoftesting.
Greensmaster
®
eFlex1800,2100and2120
Page5–67
ElectricalSystem:TestingtheElectricalComponents
12189SLRevE