TractionCircuitisInoperative(continued)
PossibleCausesCorrection
Theparkingbrakelatchswitchisnotadjusted
correctlyorisdamaged.
UsetheInfoCenterDiagnosticsscreento
checktheparkingbrakelatchswitchoperation.
Adjustorreplacetheparkingbrakelatchswitch
ifnecessary.
Thewireharnessconnectionsorwiresare
looseordamaged.
Checktheelectricalconnections.Repairthe
wireharnessasnecessary.
Aproblemexistswiththetractionorreeldrive
system.
RefertoChapter4:TractionandReelDrive
System(page4–1).
Theelectricmotorisdamaged.
Note:Faultshouldbedisplayedonthe
InfoCenteriftheelectricmotorisdamaged.
UsetheInfoCenterFaultsandDiagnostics
screenstocheckthereelcircuitoperation.
Checktheelectricmotorandcircuitwires.
Repairasnecessary.
CuttingUnitCircuitisInoperative
PossibleCausesCorrection
Thereelengageswitchisnotadjustedoris
damaged.
UsetheInfoCenterDiagnosticsscreento
checkthereelengageswitchoperation.Adjust
orreplacethereelengageswitchifnecessary.
Thewireharnessconnectionsorwiresare
looseordamaged.
Checktheelectricalconnections.Repairthe
wiringasnecessary.
Theelectricmotorisdamaged.
Note:Faultshouldbedisplayedonthe
InfoCenteriftheelectricmotorisdamaged.
Checktheelectricmotorandcircuitwires.
Repairasnecessary.
MachineisInoperativeandInfoCenterPowerLightIndicatesThataFaultHas
Occurred
PossibleCausesCorrection
Systemfaulthasbeendetectedbycontroller.UsetheFaultsscreeninformationinthe
InfoCentersectionofthischaptertohelp
identifysourceofproblem.
Anelectricalfaultoccurredthatcanbereset
bythecontroller.
Attempttorestartthemachinetoseeifthe
machineoperationhasreturnedtonormal.If
thefaultstillremains,usetheFaultsscreen
informationintheInfoCentersectionofthis
chaptertohelpidentifysourceofproblem.
Note:TheEZturnswitchhastobeON,themowcircuithastobeengaged,and
thecuttingunitneedstoberaisedbeforetheEZturnsystemwilloperate.
EZTurnSystemisNotWorking
PossibleCausesCorrection
TheEZturncircuitwireharnessconnections
orwiresarelooseordamaged.
Checktheelectricalconnections.Repairthe
wiringasnecessary.
TheEZturnswitchonthecontrolpanelis
damaged.
UsetheInfoCenterDiagnosticsscreento
checktheEZturnswitchoperation.Replace
theEZturnswitchifnecessary.
Troubleshooting:Page3–4