EasyManua.ls Logo

Toro 08743 - PTO Switch (Optional)

Toro 08743
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PTOSwitch(Optional)
POSITIONCLOSED
CIRCUITS
OFF
(DOWN)
COMB+NCB
COMC+NCC
ON(UP)COMB+NOB
COMC+NOC
Thepowertakeoff(PTO)switchislocatedonthedashpaneloftheoperators
console.ThisswitchispulleduptoengagethePTOshaftandpusheddown
todisengagethePTOshaft.
TestingthePTOSwitch
1.Parkthemachineonalevelsurface,loweranyattachments,engagethe
parkingbrake,setthekeyswitchtotheOFFpositionandremovethekey
fromtheswitch.
2.Disconnectthebatterynegative(-)cableatthebattery;refertoRemoving
andInstallingtheBattery(page6–31).
3.Removethefastenerssecuringthedashpaneltotheoperatorsconsoleand
raisethedashpanel.
4.Disconnectthewireharnessconnectorfromtheswitchandremovethe
switchfromthedashpanelifnecessary.Checktheswitchandtheharness
connectorfordamageorcorrosionandcleanorrepairifnecessary.
5.Useamultimeter(ohmssetting)andtheprecedingtabletodetermine
whethercontinuityexistsbetweenthevariousterminalsforeachswitch
position.
6.Replacetheswitchifnecessary.
7.Iftheswitchtestscorrectlyandacircuitproblemstillexists,checkthewire
harnesses;refertoAppendixA(pageA–1).
8.Installtheswitchandconnectthewireharnessaftertesting.
9.Installthedashpanel.
10.Connectthebatterynegative(-)cableatthebattery.