Inspecting,Maintaining,andTestingtheBattery(continued)
CAUTION
Followthemanufacturer'sinstructionswhenusingabatteryload
tester.
A.Checkthevoltageacrossthebatteryterminalsbeforetestingthebattery.
Ifthevoltageislessthan12.0VDC,chargethebatterybeforecontinuing
thetest.
B.Ifyouchargethebattery,applya150Aloadfor15secondstoremove
thesurfacecharge.Useabatteryloadtesterfollowingthemanufacturer's
instructions.
C.Ensurethatthebatteryterminalsarefreeofcorrosion.
D.Measuretheelectrolytetemperatureofthecentercell.
E.Connectabatteryloadtestertothebatteryterminalsfollowingthe
manufacturer'sinstructions.Connectadigitalmultimetertothebattery
terminals
F.Applyatestloadof1/2thecoldcrankingamperageratingofthebattery;
refertoBatterySpecications(page6–30).
G.Takeatestvoltagereadingwhilestillunderloadafter15seconds,then
immediatelyremovetheload.
H.UseMinimumVoltage(page6–32)todeterminetheminimumvoltagefor
thecentercellelectrolytetemperaturereading.
I.Ifthetestvoltageisbelowtheminimum,replacethebattery.Ifthetest
voltageisatorabovetheminimum,returnthebatterytoservice.
ChargingtheBattery
BatteryChargeLevel
BatteryChargeLevelSpecicGravityOpenCircuitVoltage
100%
1.26512.68
75%
1.22512.45
50%
1.19012.24
25%
1.15512.06
0%
1.12011.89
BatteryChargeRate
BatteryChargeLevel(PercentofFullyCharged)
Battery
Reserve
Capacity
(Minutes)
75%50%25%0%
80orless
3.8hrs@3A7.5hrs@3A11.3hrs@3A15hrs@3A
81to125
5.3hrs@4A10.5hrs@4A15.8hrs@4A21hrs@4A
126to170
5.5hrs@5A11hrs@5A16.5hrs@5A22hrs@5A
171to250
5.8hrs@6A11.5hrs@6A17.3hrs@6A23hrs@6A
above250
6hrs@10A12hrs@10A18hrs@10A24hrs@10A