TractionCircuitTestingChargePressureTest(continued)
Formachineswithoutbacklap,connectapressuregaugewithhydraulic
hosetothetestconnectorintheG3portofthemowermanifold;refer
toFigure27.
Forearlymachineswithbacklap,disconnectthehosefromtheelbowatthe
PTportofthemowermanifoldandinstallaswivelteeandtestconnector
tting.Connectapressuregaugewithhydraulichosetothenewlyinstalled
testconnector;refertoFigure28.
Forlatermachineswithbacklap,connectapressuregaugewithhydraulic
hosetothetestconnectoratthePTportofthemowermanifold;refer
toFigure29.
g215375
Figure30
1.Tractionpump
2.Hosefromtractionpump“A”port
5.Disconnecthosefromtractionpump“A”port;refertoFigure30.
6.Installtesterinserieswiththepumpandthedisconnectedhose.Makesure
thetesterisinstalledinthecorrectowdirectionandthetesterowcontrol
valveisfullyopen.
7.Attachaheavychaintotherearofthemachineframeandanimmovable
objecttopreventthemachinefrommovingduringtesting.
8.Chockthewheelstopreventwheelrotationduringtesting.
9.Startengine.Movethrottletofullspeed(2850±50RPM).
10.Makesurehydraulicuidisatnormaloperatingtemperaturebyoperatingthe
machineforapproximately10minutes.
11.Verifyandrecordenginespeedwithaphototach.
12.RecordthereadingonpressuregaugefromthePTportofthemower
manifold(notthepressuregaugeontheowmeter).Chargepressure
(withoutload)shouldreadapproximately414kPa(60PSI).Ifchargerelief
pressurespecicationisnotmet,considerthefollowing:
HydraulicSystem:TestingtheHydraulicSystem
Page4–42