EasyManua.ls Logo

Toro Multi Pro WM - Sprayer Calibration Procedures

Toro Multi Pro WM
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Important:Disposeofallwastechemicals
accordingtolocalcodesandthematerial
manufacturer'sinstructions.
g208237
Figure86
1.Valveclosed2.Valveopen
4.Closethedrainvalve(Figure86).
5.Fillthetankwithatleast190L(50USgallons)
ofcleanfreshwaterandclosethecover.
Note:Youcanuseacleaning/neutralizing
agentinthewaterasneeded.Onthenalrinse,
useonlyclean,clearwater.
6.Lowertheboomsintothesprayposition.
7.Starttheengineandmovethethrottleleverto
ahigheridle.
8.EnsurethattheagitationswitchisintheON
position.
9.Turnonthesprayerpumpandusethe
application-rateswitchtoincreasethepressure
toahighsetting.
10.Setthemaster-boomswitchandboom-control
switchestotheONpositionstobeginspraying.
11.Allowallofthewaterinthetanktosprayout
thoughthenozzles.
12.Checkthenozzlestoensurethattheyareall
sprayingcorrectly.
13.Setthemaster-boomswitchtotheOFFposition,
shutoffthesprayerpump,andshutoffthe
engine.
14.Repeatsteps5through13atleast2moretimes
toensurethatthespraysystemisfullycleaned.
Important:Youmustalwayscompletethis
procedureatleast3timestoensurethat
thespraysystemisfullyclean,preventing
damagetothesystem.
15.Cleanthesuctionlterandpressurelter;refer
toCleaningtheSuctionFilter(page54)and
CleaningthePressureFilter(page54).
Important:Ifyouusedwettablepowder
chemicals,cleanthestraineraftereachtank.
16.Usingagardenhose,rinseofftheoutsideofthe
sprayerwithcleanwater.
17.Removethenozzlesandcleanthembyhand.
Replacedamagedorwornnozzles.
CalibratingtheSprayer
PreparingtheMachinefor
Calibration
Important:Beforecalibratingthesprayersystem
usedontheHDX-Automodel,llthesprayer
tankasrequiredwithcleanwaterandoperatethe
machinewhilesprayingat2.75bar(40psi)or
greaterforaminimumof30minutes.
Note:Beforeusingthesprayerforthersttime,if
youchangethenozzles,orasneeded,calibratethe
sprayerow,speed,andboombypass.
1.Fillthespraytankwithcleanwater.
Note:Ensurethatthereisenoughwaterin
thetanktocompleteeachofthecalibration
procedures.
2.Lowertheleftandrightboomsections.
3.FortheHDX-Automodel—operatethemachine
whilesprayingat2.75bar(40psi)orgreaterfor
aminimumof30minutes.Fillthesprayertank
withcleanwaterwhennished.
4.Settheprotectedsettingstooff;refertoSetting
theProtectSettings(page52).
5.FortheHDX-Automodel—setthesprayer
systemtotheManualMode;refertoSwitching
betweenManualModeandAutomaticMode
(page48).
CalibratingtheSprayerFlow
Operatorsuppliedequipment:Stopwatchcapable
ofmeasuringto±1/10secondandacontainer
graduatedin50ml(1oz)increments.
Note:Calibratingthesprayerowformachines
withoutathrottlelockrequires2people.
1.Setthetransmissionasfollows:
ForHD-SeriesModelswithamanual
transmission—shiftthetransmissiontothe
NEUTRALposition.
FortheHDX-Automodel—shiftthe
transmissiontoP(park).
2.Engagetheparkingbrakeandstarttheengine.
3.Turnonthesprayerpumpandturnonthe
agitation.
60

Table of Contents

Related product manuals