DISASSEMBLY AND REPLACEMENT
4 - 161
4.12.10 ADU motor (M5) <20ppm/25ppm/30ppm>
(1) Remove the ADU guide assembly.
P. 4-154 "4.12.4 ADU guide assembly
<20ppm/25ppm/30ppm>"
(2) Remove 2 screws from the ADU guide
assembly [1].
Fig. 4-430
(3) Disconnect 1 connector and remove the
ADU motor assembly [2].
Fig. 4-431
(4) Remove 2 screws, and take off the ADU
motor [3].
Fig. 4-432