SETTING / ADJUSTMENT
6 - 58
6.12 Adjustment of the RADF
6.12.1 Adjustment of RADF position
Perform this adjustment when the RADF is not installed in the correct position.
Notes:
Check if the image adjustment for the equipment is performed properly before this adjustment of
the RADF.
[A] Checking
(1) Change the screws of left and right.
(2) Open the RADF and install 2 positioning pins
(the positioning pins are installed to the back
side of the hinge which is on the left side of
the RADF).
Fig.6-48
(3) Remove the platen sheet.
Fig.6-49
(4) Close the RADF and check if the positioning
pins fit the holes on the RADF.
Fig.6-50