9
© 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
REPLACEMENT OF PC BOARDS/HDD
9 - 23
9.2.5 Procedures when replacing the LGC board
Notes:
Before replacing the LGC board, perform the following procedure.
P. 9-11 "9.2.1 Precautions when replacing PC boards"
The LGC board differs depending on the speed of the equipment.
Before replacing it, check that the speed (referring to the identification label, etc.) corresponds to
the label color (indicated by the arrow) on the LGC board as shown below.
If not, F901 or F901_1 occurs.
Combination of the speed and the label color
20ppm: White
25ppm: Pink
30ppm: Blue
35ppm: Yellow
45ppm: Green
50ppm: Red
Fig. 9-30
Be sure to follow the procedure below when the LGC board is replaced.
(1) Perform [FS-08-4581] to copy the data in SRAM to EEPROM.
If you cannot start up with the 08 Setting Mode, begin from step (2).
(2) Turn the power OFF.
(3) Remove the LGC board.
P. 9-5 "9.1.4 LGC board"
(4) Install the removed LGC board’s EEPROM into the new LGC board’s IC29.
(5) Attach a battery to the new LGC board.